česká verze
česká verze
english version
english version
Basic information about DAGGER
Address, estabilishment, phone number, e-mail
Diesel power generating units provided by DAGGER
Gas combined heat and power units
Service by DAGGER
References, Our customers
Form is sent directly to DAGGER
.: NEWS
.: 21.01.2015 - registration form HERE

GAS COMBINED HEAT AND POWER UNITS (CHP)

MAN  |  PERKINS


MAN
CHP type
DAGGER
gas engines fuel mixture
cooling temp. [°C]
el.output
[kWe]
heat rate
[kWt]
gas consumption
[Nm3/h]
type fuel
MAN Nutzfahrzeuge enginesZPBP, SP
CMG 70E0836 E302ZP-7010921-

CMG 100E0836 LE302BP, SP50103138-46
CMG 100ZP5010313828-
CMG 100ZP8010315129-

CMG 120E2876 TE302BP, SP-123181-58
CMG 140ZP-14121140-

CMG 190E2876 LE302BP, SP50190244-83
CMG 200ZP5020026354-
CMG 200ZP8020029356-

CMG 300E2842 LE312BP, SP80308460-143
CMG 340BP, SP50345432-155
CMG 340ZP8034548194-
CMG 380ZP50384467104-

To top   

PERKINS
CHP type
DAGGER
gas engines fuel mixture
cooling temp. [°C]
el.output
[kWe]
heat rate
[kWt]
gas consumption
[Nm3/h]
type version-fuel
PERKINS enginesZPBPSP
CPG 3004006 TESIHC - BP, SP40308405-133158
LC - BP, SP34308432-136161
HC - ZP7530843987--

CPG 3004006-23TRS1 - ZP, BP, SP4530837883127150
CPG 370TRS2 - ZP4537742899--

CPG 4104008 TESIHC - BP, SP40414549-179212
LC - BP, SP34414606-188222
HC - ZP75414594117--

CPG 4304008-30TRS1 - ZP, BP, SP40432510116178210
CPG 500TRS2 - ZP40506579132--

CPG 6004012 TESIHC - BP, SP40606796-264312
LC - BP, SP34606868-272322
HC - ZP75606881171--

CPG 6004012-45TRS1 - ZP, BP, SP40606735162250295
CPG 760TRS2 - ZP40762831198--

CPG 8104016 TESIHC - BP, SP408141 145-354418
LC - BP, SP348141 229-376444
HC - ZP758141 234230--

CPG 9004016-61TRS1 - ZP, BP, SP409071 022241371438
CPG 1000TRS2 - ZP401 0081 155261--

CPG 10004016 E61TRS - ZP401 0081 220259--

To top   

Rem. Conditions:
- Standard CHP unit operation generates both power and heat in automatic mode 24 hours a day. - Output power acc. to ISO 3046 at power factor cos fi=1, heat performance : water 70/90 °C.
- Stand-alone or parallel operation with network 400 V, 3-phase, 50 Hz with automatic control of voltage and power factor.
- For other network parameters or other heating systems technical specification upon request.
- All information for fuel other than natural gas is indicative only – the resp. inquiry must include the chemical analysis of the specific fuel.
- Engines to run for biogas or landfill gas are delivered in special execution with parts highly resistent against low quality fuel effects.

MAN engines
- Typical fuels: descriptions : ZP = natural gas with CH4 contents 100 %, methane no. more than 80, BP = bio gas, SP= landfill gas CH4 contents 60 %, methane no. more than 100, continuous operation until 1st general overhaul at least 50.000 hours.

PERKINS engines
- typical fuels : descriptions : ZP = natural gas with CH4 contents 100 %, methane no. more than 75, BP = bio gas CH4 contents 65%, SP= landfill gas CH4 contents 55 %, methane no. more than 65, continuous operation until 1st general overhaul at least 50.000 hours, in case of CPG 1000 the general overhaul takes place after 64.000 hours at the earliest. The engines marked „TRS“ are working with enhanced electrical efficiency.
- The engines marked „HC“ for natural gas guarantee, at the nominal electric power output, the production of the indicated quantity of heat for recuperative water at 70°C, including 100 % utilization of the heat recovered from the charge cooler.